ALOM supports incoming serial modem communication from an external modem for remote management. To accept an incoming communication, you need to configure the modem hardware and ALOM software locally before accessing the system remotely.
A modem attached to the serial management port (SERIAL MGT) has exclusive use of the port. You may want to configure ALOM for use on an Ethernet to allow local users to connect to ALOM via Telnet. See Configuring ALOM or Configuring Your Network Manually for further information.
sc> setsc if_modem
true
# scadm set
if_modem true
May 19 13:59:07 wgs40-232 rmclomv: Serial Mgt port
input is disabled until a modem call is received
SC Alert: Serial Mgt port input is disabled until a modem call is received
Note: After you set the if_modem variable to true, input on the serial connection is disabled unless either the DCD signal on the serial management port goes high or the if_modem variable is set back to false. You will not be able to use the SERIAL MGT port until you connect a modem to it. However, you can use telnet to connect to ALOM through the NET MGT port.
if_modem
variable to false
by doing one of the following:sc> setsc if_modem
false
scadm set if_modem
false
Issue | Solution |
ALOM modem does not answer | Verify that cabling is set up correctly. See Setting Up the Hardware for additional information. |
ALOM modem answers then immediately hangs up | Verify that the if_modem variable is set to true. |
ALOM modem answers but connections appear dead |
|