Previous  
Product: Cluster Server Enterprise Agents Guides   
Manual: Cluster Server 4.1 Enterprise Agent for Hitachi TrueCopy Installation and Configuration Guide   

Verifying a Successful Fire Drill

Bring the fire drill service group online on a node that does not have the application running. Verify that the fire drill service group comes online. This action validates that your disaster recovery solution is configured correctly and the production service group will fail over to the secondary site in the event of an actual failure (disaster) at the primary site.

If the fire drill service group does not come online, review the VCS Engine log to troubleshoot the issues so that corrective action can be taken as necessary in the production service group. You can also view the fire drill log, located at /tmp/fd-servicegroup.


Caution  Caution    Remember to take the fire drill offline once its functioning has been validated. Failing to take the fire drill offline could cause failures in your environment. For example, if the application service group were to fail over to the node hosting the fire drill service group, there would be resource conflicts, resulting in both service groups faulting.
 ^ Return to Top Previous  
Product: Cluster Server Enterprise Agents Guides  
Manual: Cluster Server 4.1 Enterprise Agent for Hitachi TrueCopy Installation and Configuration Guide  
VERITAS Software Corporation