Document ID Synopsis Date 16524 E450 only shows 4 disks under prtdiag 1 Jun 2000
Problem Description When users run prtdiag -v on the Enterprise 450 fully configured with disks they can only see a max of 4 disks e.g. Disk LED Status: OK = GREEN ERROR = YELLOW DISK 18: [EMPTY] DISK 19: [EMPTY] DISK 16: [EMPTY] DISK 17: [EMPTY] DISK 14: [EMPTY] DISK 15: [EMPTY] DISK 12: [EMPTY] DISK 13: [EMPTY] DISK 10: [EMPTY] DISK 11: [EMPTY] DISK 8: [EMPTY] DISK 9: [EMPTY] DISK 6: [EMPTY] DISK 7: [EMPTY] DISK 4: [EMPTY] DISK 5: [EMPTY] DISK 2: [OK] DISK 3: [OK] DISK 0: [OK] DISK 1: [OK]
Problem Solution From the OBP prompt: ok setenv disk-led-assoc 0 x y where x= 1 to 10 PCI slot where the lowest Ultrascsi cont is installed where y= 1 to 10 PCI slot where the uppermost Ultrascsi cont is installed For example, if ctrl cards are in slot 5 and 7 enter the following: ok setenv disk-led-assoc 0 5 7 if there is only one ctrl installed in slot 5 ok setenv disk-led-assoc 0 5 ok reset ok boot -r to take effect Now run prtdiag -v Disk LED Status: OK = GREEN ERROR = YELLOW DISK 18: [OK] DISK 19: [OK] DISK 16: [OK] DISK 17: [OK] DISK 14: [OK] DISK 15: [OK] DISK 12: [OK] DISK 13: [OK] DISK 10: [OK] DISK 11: [OK] DISK 8: [OK] DISK 9: [OK] DISK 6: [OK] DISK 7: [OK] DISK 4: [OK] DISK 5: [OK] DISK 2: [OK] DISK 3: [OK] DISK 0: [OK] DISK 1: [OK]
Applies To Hardware, Hardware/Ultra Enterprise/Servers/Enterprise 450, Operating Systems/Solaris/Solaris 2.x, AFO Vertical Team Docs, AFO Vertical Team Docs/Hardware Attachments (none) Document Content SRDB ID: 16524